VTech Process Equipment LLC | Process Equipment for HVAC/R Assembly Lines

Electrical Safety and Performance Test

(Click on thumbnail to enlarge)

Electrical Safety and Performance Test
Electrical Safety and Performance Test

Electrical Safety and Performance Test
Electrical Safety and Performance Test

VTech's ST Series of Electrical Safety Test Equipment verifies the correct operation of refrigeration and air conditioning units, built with either 1ph or 3 ph power. The framework consists of a PC control cabinet and interchangeable testing modules, allowing the end user to select the types of tests they desire including Earth Continuity, Insulation Resistance, Dielectric Strength, Earth Leakage current and Power Consumption. Special adaptations, for example to test with the unit under power, can be made as well.

VTech's PT Series of Performance Test Equipment can test units operating at 1ph or 3ph power. Using a central control and data-collection system connected by wire or wirelessly to data acquisition boxes, which communicate with the hub, measure performance values over time. Key factors such as the time of the test, whether or not there is a defrost cycle and how many temperatures are to be recorded during the cycle, all come into play when determining how many data acquisitions boxes are required to meet productivity.

Each system can be interfaced with the plant's information network and data is recorded and stored for quality control purposes.

VTech Electrical Safety & Performance Test EQUIPMENT

   
Electrical Safety Test Types Specification Value
Earth Continuity
(Ground Bond)
Test Current 25A
Max Output Voltage 10V AC
Range 0-3A
Accuracy f.s. 1%
Displayed Values -Measured resistance
-Test current
Programmable Values -Test current
-Max resistance allowed
-Test time
Insulation Resistance with Power On Test Voltage 1-10M
Max Current 10 mA
Range 1-10M
Accuracy f.s. 1-10M 1%
Displayed Values -Test voltage
-Measured resistance
Programmable Values -Minimum resistance allowed
-Test time
Dielectric Strength
(Hi-Pot) with Power On
Test Voltage 0-1,500V AC
Max Current 10 mA
Range 0-10 mA
Accuracy f.s. 1%
Displayed Values -Test voltage
-RMS measured current (active component)
Programmable Values -Maximum current allowed
-Test time
Earth Leakage Current Test Voltage Vn+10%
Max Current 0-10 mA
Accuracy f.s. RMS1%
Displayed Values -Test voltage
-RMS measured current for each phase
Programmable Values -Maximum current allowed
-Test time
Current Consumption Output voltage 240 V AC 50
Max current 15A
Accuracy f.s. 1%
Displayed Values -Current
-Voltage
Programmable Values -Current
-Tolerance
-Delay before starting the Acquisition
-Test voltage

Electrical Safety accessories:

  • 1ph/3ph calibration boxes
  • Remote control boxes (start, stop, restore, emergency, OK, NOK)
  • Ground plier with Start button
  • Automatic Input Switch 50/60 Hz 1ph/3ph
  • High Accuracy Wattmeters 16A/20A
  • Power Supply with Variable AC (115 ± 25% e 230 ± 25% vf ± 5%)
  • Test with Unit Powered
  • CCD/RF Barcode readers
  • Printer
  • Excel traceability

Performance Test accessories:

  • Automatic switch input 50/60Hz or 110/230V
  • NTC Temperature Sensor -50+100 ±0.4°C L=5m (with or without pipe plier)